Graco 333492B User Manual

Browse online or download User Manual for Unknown Graco 333492B. Graco 333492B User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
333492B
EN
INSTRUCTIONS
SDMM8 Manual Meter and
SDMP8 Preset Meter
For metered dispense of petroleum-based lubricants, oils and 50:50 antifreeze/water mix
fluids only.
For professional use only.
Maximum Working Pressure: 1500 psi (10 MPa, 103 bar)
List of Models page 2
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - SDMP8 Preset Meter

333492BENINSTRUCTIONSSDMM8 Manual Meter and SDMP8 Preset MeterFor metered dispense of petroleum-based lubricants, oils and 50:50 antifreeze/water mix

Page 2 - SDMM8 Manual Bare Meters

Installation 10 333492BPre-Installation ProcedureNOTE: The letters used in the following instructions refer to Typical Installation on page 7 and the

Page 3 - SDMP8 Preset Meters

Installation333492B 114. Install extension (102) to meter:a. Loosen extension nut (102a) (FIG. 4) until it is completely off tube threads.NOTE: Do not

Page 4

Operation 12 333492BOperationNOTE: The letters used in the following instructions refer to Typical Installation on page 7 and the Compo-nent Identific

Page 5 - WARNINGWARNINGWARNING

Troubleshooting333492B 13TroubleshootingRelieve pressure, page 8, before you check or repair the meter. Be sure all other valves, controls and pump ar

Page 6

Service 14 333492BServiceCleaning / Repairing the Fluid SectionNOTE: Do not disassemble the fluid and counting sec-tions simultaneously. Confirm the f

Page 7 - Typical Installation

Service333492B 15SDMM8 Manual Meter Counter Section RepairDisassemblyNOTE: Do not disassemble the fluid and counting sec-tions simultaneously. Confirm

Page 8

Service 16 333492B7. Remove the entire counter assembly (31) (FIG. 19).Reassembly1. Install counter assembly (31).2. Install the gears (32, 34, 35) as

Page 9 - Component Identification

Service333492B 176. Install small retaining ring (43), pointer pin (41) and pointer spring (42). Install the cover (44). (FIG. 25). SDMP8 Preset Meter

Page 10 - Installation Procedure

Service 18 333492B6. Remove the entire counter assembly (31) (FIG. 30).Reassembly1. Install counter assembly (31) (FIG. 31).2. Install the gears (32,

Page 11 - 333492B 11

SDMM8 Manual Meter Parts333492B 19SDMM8 Manual Meter PartsModels 24U959, 24U960, 24U961, 24U956, 24U957, 24U95813b3a5869101121612131415164649454748293

Page 12 - Operation

Models 2 333492BModelsSDMM8 Manual Bare MetersBare manual meters do not include a nozzle or extension. Model packages that include a nozzle and extens

Page 13 - Troubleshooting

SDMM8 Manual Meter Parts 20 333492BSDMM8 Manual Meter PartsModels 24U959, 24U960, 24U961, 24U956, 24U957, 24U958 Parts are included in Kit 24V460† Pa

Page 14 - Service

SDMP8 Preset Meter Parts333492B 21SDMP8 Preset Meter PartsModels 24U947, 24U948, 24U949, 24U950, 24U951, 24U952, 24U953, 24U954, 24U955444142503440393

Page 15 - Section Repair

SDMP8 Preset Meter Parts 22 333492BSDMP8 Preset Meter PartsModels 24U947, 24U948, 24U949, 24U950, 24U951, 24U952, 24U953, 24U954, 24U955Ref Part No. D

Page 16 - Reassembly

SDMP8 Preset Meter Parts333492B 23‡ Included in Kit 24V466 Included in Kit 24V472 Included in Kit 24V465 Included in Kit 24V46136 16X587 GEAR, twin

Page 17 - SDMP8 Preset Meter Counter

Nozzle (101) and Extension (102) Kits 24 333492BNozzle (101) and Extension (102) KitsKit No. Description Fluid Type255852*Automatic, non-drip quick cl

Page 18

Nozzle (101) Parts333492B 25Nozzle (101) PartsPart No. Description Qty Fluid Type255459* Automatic, non-drip, quick-close nozzle Oil• BODY, nozzle 1•

Page 19 - SDMM8 Manual Meter Parts

Technical Data 26 333492BTechnical Data*Tested in 10W motor oil. Flow rates vary with fluid pressure, temperature and viscosity.**Rolls over to 00,000

Page 20

Technical Data333492B 27DimensionsManual Meter Preset MeterFIG. 36FIG. 37

Page 21 - SDMP8 Preset Meter Parts

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Page 22

Models333492B 3The following packages include Bare Meter Model 24U957 and the nozzle and extension kits indicated in the table below.The following pac

Page 23 - 333492B 23

Models 4 333492BSDMP8 Preset Meters with Nozzle and Extension PackagesThe following packages include Bare Meter Model 24U947 and the nozzle and extens

Page 24 - 24 333492B

Warnings333492B 5WarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point s

Page 25 - Nozzle (101) Parts

Warnings 6 333492BEQUIPMENT MISUSE HAZARDMisuse can cause death or serious injury.• Do not operate the unit when fatigued or under the influence of dr

Page 26 - Technical Data

Typical Installation333492B 7Typical InstallationKey:A Main air supply lineB Pump air supply lineCAir filterD Air regulatorE Bleed-type master air val

Page 27 - Dimensions

Installation 8 333492BInstallationNOTE: The letters used in the following instructions refer to Typical Installation on page 7.Pressure Relief Procedu

Page 28 - Graco Information

Installation333492B 9Component IdentificationKey:1 Swivel12 Trigger37 Meter dial41 Meter pointer101 Nozzle102 ExtensionFIG. 21124137102101