Installation
NOTES:
D Reference numbers and letters in parentheses in the text refer to the callouts in the figures and drawings.
D Always use Genuine Graco Parts and Accessories, available from your Graco distributor.
Grounding
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE OR EXPLOSION
HAZARD on page 3.
Ground all of this equipment:
D Pump: Use a ground wire and clamp as shown in
Fig. 1. Remove the ground screw (Z) and insert
through the eye of the ring terminal at end of
ground wire (Y). Fasten the ground screw back
onto the pump and tighten securely. To order a
ground wire and clamp, order part number 222011.
Fig. 1
TI1052
Y
Z
D Air and fluid hoses: Use only electrically conductive
hoses.
D Air compressor: Follow manufacturer’s recommen-
dations.
D Dispensing valve: Ground through connection to a
properly grounded fluid hose and pump.
D Object being dispensed to: Follow your local code.
D Solvent pails used when flushing: Follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
D To maintain grounding continuity when flushing or
relieving pressure, hold a metal part of the dispens-
ing valve firmly to the side of a grounded metal pail,
then trigger the dispense valve.
Page view 3