Instructions - Parts
Warm Melt Supply
Systems
For use with heated bulk supply of medium to high viscosity sealant and adhesive
materials. Not for use in hazardous locations. Intended for indoor use only.
D60 3 inch dual post
60 liter (16 gallon), 30 liter (8 gallon), and
20 liter (5 gallon) sizes
150 psi (1.0 MPa, 10 bar) Maximum Air Inlet Pressure
D200 3 inch dual post
200 liter (55 gallon)
150 psi (1.0 MPa, 10 bar) Maximum Air Inlet Pressure
D200S 6.5 inch dual post
200 liter (55 gallon)
125 psi (0.9 MPa, 9 bar) Maximum Air Inlet Pressure
See page 4 for model information.
The Graco Control Architecture Electric Components
are listed in Intertek’s Directory of Listed Products.
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
D200s (WM2179) Shown
313296J
EN
Page view 0
1 2 3 4 5 6 ... 107 108

Summary of Contents

Page 1 - Warm Melt Supply

Instructions - PartsWarm Melt Supply SystemsFor use with heated bulk supply of medium to high viscosity sealant and adhesive materials. Not for use in

Page 2 - Contents

Component Identification 10 313296JNOTE: See FIG. 2 and FIG. 3. Before you install the system, you should be familiar with the following compo-nents.

Page 3 - Related Manuals

Appendix A - User Interface Display 100 313296JRun Mode ScreensRun mode screens are divided into six sections: ram operation, heat zone operation, cur

Page 4 - 4 313296J

Appendix A - User Interface Display313296J 101Heat Run ScreenThe Heat Run screen displays information for four to six heat zones. See FIG. 72 for info

Page 5 - Warnings

Appendix A - User Interface Display 102 313296JStatus ScreenThis screen displays the job totals and grand totals. If there is a filter or an error iss

Page 6 - 6 313296J

Appendix A - User Interface Display313296J 103Alarm ScreenThe alarm screens display the type of alarm currently occurring on each ram. Once an alarm i

Page 7 - Overview

Dimensions 104 313296JDimensionsD200 ModelsD200s ShownCGEFDB(ram down)A(ram up)Ram ModelAin. (mm)Bin. (mm)Cin. (mm)Din. (mm)Ein. (mm)Fin. (mm)Gin. (mm

Page 8 - Component Identification

Dimensions313296J 105D60 ModelsCGEFDB(ram down)A(ram up)Ram ModelAin. (mm)Bin. (mm)Cin. (mm)Din. (mm)Ein. (mm)Fin. (mm)Gin. (mm)D6092.7 (2355) 62.7 (1

Page 9 - Tandem Supply Systems

Technical Data 106 313296JTechnical DataMaximum Fluid Working Pressure and Flow Rate at Full Air Pressure (100 psi)WeightSee the identification plate

Page 10 - Integrated Air Controls

Technical Data313296J 107

Page 11 - Communications Gateway

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Page 12 - Fluid Control Module

Component Identification313296J 11Air Line AccessoriesSee Supply Systems Operation manual.• Air line drain valve. Not included.• Air line filter: remo

Page 13 - User Interface

Component Identification 12 313296JFluid Control ModuleTable 2: FCM Sensor ConnectionsConnection Ram Sensor Description1 Ram A and Ram B Air motor sol

Page 14 - Single ram:

Component Identification313296J 13User InterfaceFIG. 8: Display ModuleTable 3: Display Module Button FunctionsButton FunctionOn/OffPowers air motor so

Page 15 - 313296J 15

Component Identification 14 313296JSoft KeySoft keys activate the mode or action represented by the icon above each button in the LCD. See Table 4 for

Page 16 - User Interface Display

Component Identification313296J 15Crossover Crossover key transitions the active ram to inactive, and inactive ram to active. Available on Warm Melt T

Page 17 - Installation

Component Identification 16 313296JUser Interface DisplayNOTE: For details regarding the user interface dis-play see Appendix A - User Interface Displ

Page 18 - Connect Power Source

Installation313296J 17InstallationAccessories are available from Graco. Make certain all accessories are adequately sized and pressure-rated to meet t

Page 19 - Light Tower Accessory

Installation 18 313296JFluid supply container: follow local code.Object being sprayed: follow local code.Solvent pails used when flushing: follow loca

Page 20 - Attach Drum Stops

Installation313296J 19Install/Adjust Drum Low or Empty Sensor1. Position ram at desired level (low or empty).NOTE: Follow Steps 2 through 4 only if in

Page 21 - Check Resistance

2 313296JContentsRelated Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Models . . . . . . . . . . . . . . . . . . . . .

Page 22 - Heater Resistance Checks

Installation 20 313296JAttach Drum StopsSupply systems are shipped with drum stops in place to help position the drum on the ram. For replacement part

Page 23 - Control Settings

Installation313296J 21Check ResistanceCheck the Resistance Between the Supply System and the True Earth GroundHave a qualified electrician check the r

Page 24 - Set Values on Display Module

Installation 22 313296JHeater Resistance ChecksNOTE: For dispense valve and hose sensor resis-tance checks, refer to your dispense valve manual or hos

Page 25 - Load Material

Installation313296J 23Hose Installation and CareNOTE: The warm melt supply system requires Graco single-circuit material hoses rated at a maxi-mum of

Page 26 - System Heat Up

Setup 24 313296JSetupThe pump was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid contaminat-ing fluid wit

Page 27 - 313296J 27

Setup313296J 25Load MaterialNOTE: Before loading material, ensure that there is a minimum overhead clearance of 105 in. (267 cm) and all air regulator

Page 28 - Operation

Setup 26 313296JSystem Heat UpNOTE: Operate at the lowest temperature and pres-sure necessary for your application.1. Turn the main disconnect on the

Page 29 - Manual Crossover

Setup313296J 27Prime 1. Make sure the system is at required temperature.2. Tandem Systems Only: To prime the active ram, ensure that the system is not

Page 30 - Depressurize Function

Operation 28 313296JOperationPressure Relief ProcedureThis procedure describes how to relieve pressure for the supply system. Use this procedure whene

Page 31 - Change Drums

Operation313296J 293. Press while in the Ram Operation screen. 4. When the confirmation screen appears with a prompt, select to start the pump.5.

Page 32 - Maintenance

Related Manuals313296J 3Related ManualsManuals are available at www.graco.com.Component Manuals in U.S. English:Manual Description313528 Tandem Supply

Page 33 - Platen Maintenance

Operation 30 313296JRecirculate FunctionRecirculate mode pumps fluid from the drum, through the pump, and back into the drum on the currently active r

Page 34 - Electrical Enclosure

Operation313296J 31NOTE: Depressurizing the active ram will depressurize both rams. However, if additional user-supplied check valves have been added

Page 35 - Pump Heaters

Maintenance 32 313296JShutdownFollow the procedure below for normal system shut down, such as at the end of the work day.NOTE: The ram up/down and blo

Page 36 - Clear Alarms

Maintenance313296J 33Platen MaintenanceIf the platen does not come out of the pail easily when the pump is being raised, the air assist tube or check

Page 37 - 313296J 37

Maintenance 34 313296JElectrical Enclosure1. Turn the main disconnect on the electrical control panel door to the OFF position to disconnect power.2.

Page 38 - 38 313296J

Maintenance313296J 35Pump Heaters1. Turn the main disconnect on the electrical control panel door to the OFF position to disconnect power.2. Remove fo

Page 39 - 313296J 39

Alarms 36 313296JAlarmsWarm Melt alarms alert you to a problem and help pre-vent system shutdown or application errors. If an alarm occurs, operation

Page 40 - 40 313296J

Alarms313296J 37Fluid Control Module (continued)DA1XDA2XPump Runaway APump Runaway BPump is running faster than set runaway limit due to:•Increased ai

Page 41 - 313296J 41

Alarms 38 313296JFluid Control Module (continued)DA1XDA2XPump Runaway APump Runaway BPump is running faster than set runaway limit due to:•Increased a

Page 42 - 42 313296J

Alarms313296J 39Fluid Control Module (continued)DD1XDD2XA - Pump Diving B - Pump Diving Pump leak. Worn valve or packings. See Check-Mate Displace-men

Page 43 - 313296J 43

Models 4 313296JModelsCheck the identification plate (ID) for the 6-digit part number of your warm melt supply system. Use the following matrix to def

Page 44 - Troubleshooting

Alarms 40 313296JTemperature Control Modules (continued)T6A1T6A2T6A3T6A4T6A5T6A6T6A7T6A8T6A9T6A10T6A11T6A12No Temp Rise Tripped circuit breaker. Visua

Page 45 - 313296J 45

Alarms313296J 41Temperature Control Modules (continued)A1A1A1A2A1A3A1A4A1A5A1A6A1A7A1A8A1A9A1A10A1A11A1A12Undercurrent Tripped circuit breaker. Visual

Page 46 - 46 313296J

Alarms 42 313296JT4C1T4C2T4C3T4C4T4C5T4C6T4C7T4C8T4C9T4C10T4C11T4C12PCB Overtemperature Overheated Temperature Control Module.Turn heat zone off. Wait

Page 47 - Air Motor

Alarms313296J 43Temperature Control Modules (continued)V1I1V1I2V1I3V1I4V1I5V1I6V1I7V1I8V1I9V1I10V1I11V1I12Low DC Voltage Faulty DC power supply. Measu

Page 48 - Displacement Pump

Troubleshooting 44 313296JTroubleshootingNOTE: Troubleshooting covered in this manual is specific to warm melt heat functions. Refer to Sup-ply System

Page 49 - Install Displacement Pump

Troubleshooting313296J 45No heat. Tripped circuit breaker. Visually check circuit breaker for a tripped condi-tion.Determine cause of tripped circuit

Page 50 - Disconnect Pump from Platen

Troubleshooting 46 313296JMissing module. Modules not on network. Verify attached modules through Advanced Setup screens 4 and 5.Enter Setup screen an

Page 51 - Replace Pump Heaters

Repair313296J 47RepairAir MotorRemove Air MotorRemove junction box.For 55 gallon platen (D200 and D200s supply systems): Remove two screws (61) securi

Page 52 - Replace Platen Heaters and

Repair 48 313296JInstall Air Motor1. See Supply System repair manual for air motor installation instructions.2. Reinstall junction box.For 55 gallon p

Page 53 - 313296J 53

Repair313296J 49D60 Supply System1. Disconnect air hose and ground wire from air motor.2. See Disconnect Displacement Pump in Check-Mate Pump Packages

Page 54 - Replace Ram Piston Rod Seals

Warnings313296J 5WarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point s

Page 55

Repair 50 313296JDisconnect Pump from PlatenThe pump is mounted to the platens by mounting Kit 255392.55 Gallon Platen1. Disconnect displacement pump

Page 56 - Software

Repair313296J 51Connect Pump to Platen55 Gallon Platen1. Use two people to set pump onto platen.2. Secure pump to platen with screws (103a) and clamps

Page 57 - Replace Electrical Enclosure

Repair 52 313296J5. Remove pump heater bands (44 or 227):a. Remove screws from both pump heaters.b. Pry heater bands apart and remove from pump.c. Dis

Page 58 - Display/User Interface

Repair313296J 53d. Remove screws (58) and washers (82). Remove platen heater blocks (43) and RTD sensor (46). 5. Install new platen heaters and RTD se

Page 59 - Replace Fluid Control Module

Repair 54 313296JReplace Platen WipersRefer to Supply Systems Repair-Parts manual for instructions.Replace Ram Piston Rod Seals1. Support electrical e

Page 60 - Replace Cable Track

Repair313296J 55Electrical EnclosurePrior to repairing any component of the electrical enclo-sure (13 or 14), turn the main disconnect on the electri-

Page 61 - Electrical Schematics

Repair 56 313296JReplace Base1. Remove low power TCM. See Replace Low Power Temperature Control Module(s).2. Disconnect two CAN cables from base (407)

Page 62 - D200 Ram A Schematic

Repair313296J 57Replace Circuit Breakers1. Open enclosure door (402). Disconnect wires from circuit breaker (417, 419).2. Push in circuit breaker tab

Page 63 - Schematic

Repair 58 313296JDisplay/User InterfaceUpgrade Display SoftwareNOTE: Order kit 16C027 for an upgrade token. See Graco Control Architecture™ Module Pro

Page 64

Repair313296J 59Replace Fluid Control Module1. Disconnect power to system.2. Remove front shroud (16 or 204) and back shroud (17 or 205).3. Disconnect

Page 65 - D200 Junction Box Schematic

Warnings 6 313296JMOVING PARTS HAZARDMoving parts can pinch or amputate fingers and other body parts.• Keep clear of moving parts.• Do not operate equ

Page 66 - D200 Cable Track Schematic

Repair 60 313296JReplace Cable TrackD200 and D200S Supply Systems OnlyNOTE: Order Kit 257163 for replacement.1. Disconnect power to system.2. Disconne

Page 67 - D60 Single Ram Schematic

Electrical Schematics313296J 61Electrical SchematicsWarm Melt EnclosurePower (1)Low Sensor (2)Common (3)1(2) N/C(3) Motor Reed Up(5) Motor Reed Com5(7

Page 68 - D60 Ram A Schematic

Electrical Schematics 62 313296JWarm Melt EnclosurePower (1)Low Sensor (2)Common (3)1(2) N/C(3) Motor Reed Up(5) Motor Reed Com5(7) Linear Com-24Vdc (

Page 69 - D60 Ram B

Electrical Schematics313296J 63-24Vdc (3)+24Vdc (2)CAN_H (4)CAN_L (5)SHLD (1)-24Vdc (3)+24Vdc (2)CAN_H (4)CAN_L (5)SHLD (1)FLUID CONTROLMODULERAM “B”C

Page 70 - D60 Pump and Platen Schematic

Electrical Schematics 64 313296JD200 Displacement Pump and Platen SchematicsPlatenDisplacement Pump

Page 71 - D60 Junction Box Schematic

Electrical Schematics313296J 65D200 Junction Box Schematic

Page 72 - D60 Cable Harness Schematic

Electrical Schematics 66 313296JD200 Cable Track Schematic

Page 73

Electrical Schematics313296J 67Warm Melt EnclosurePower (1)Low Sensor (2)Common (3)1(2) N/C(3) Motor Reed Up(5) Motor Reed Com5(7) Linear Com-24Vdc (3

Page 74

Electrical Schematics 68 313296JWarm Melt EnclosurePower (1)Low Sensor (2)Common (3)1(2) N/C(3) Motor Reed Up(5) Motor Reed Com5(7) Linear Com-24Vdc (

Page 75 - 313296J 75

Electrical Schematics313296J 69-24Vdc (3)+24Vdc (2)CAN_H (4)CAN_L (5)SHLD (1)-24Vdc (3)+24Vdc (2)CAN_H (4)CAN_L (5)SHLD (1)FLUID CONTROLMODULERAM “B”C

Page 76 - 76 313296J

Overview313296J 7OverviewSystem DescriptionWarm melt supply systems are used for melting and pumping warm melt adhesives and high viscosity seal-ants.

Page 77 - 313296J 77

Electrical Schematics 70 313296JD60 Pump and Platen Schematic

Page 78 - Kit 24D016 Shown

Electrical Schematics313296J 71D60 Junction Box Schematic

Page 79 - 313296J 79

Electrical Schematics 72 313296JD60 Cable Harness Schematic

Page 80 - 80 313296J

Electrical Schematics313296J 73Electrical Enclosure Schematic4-Zone Medium Enclosure

Page 81 - UBFB

Electrical Schematics 74 313296JElectrical Enclosure Schematic4-Zone RAM ‘B’ Enclosure

Page 82 - 82 313296J

Electrical Schematics313296J 75

Page 83 - Kit 24D010 Shown

Parts 76 313296JPartsD200s Rams ShownSingle Supply System or Supply System ASupply System B55436161577141336422

Page 84 - 84 313296J

Parts313296J 77NOTE: See Component Identification, starting on page 8, to identify the components included in your Warm Melt supply system.❄See Supply

Page 85 - 313296J 85

Parts 78 313296JWarm Melt Kits for D200 SystemsKit 24D012 (CST), 24K675 (SST) with Display for D200 and D200i SystemsKit 24D015 (CST), 24K678 (SST) wi

Page 86

Parts313296J 79421018883, 84, 8511, 123911, 26, 58, 594053547180528610161, 6272, 7378TI19984a

Page 87 - 313296J 87

Component Identification 8 313296JComponent IdentificationSingle Supply Systems Key:ARam AssemblyC Air MotorD Heated Check-Mate Displacement PumpE Hea

Page 88 - Platen 24D066 (20L) Shown

Parts 80 313296J4457, 99518770634968, 69, 97, 984645, 79484359641157, 97, 100, 10246, 56, 82103a103b103c1Torque to 60 +/- 10 in-lbs (6.8 +/- 1.1 N•m)1

Page 89 - 313296J 89

Parts313296J 81D200 Warm Melt KitsUBFB9392949591115910111659119011368, 97, 98891171121159Ref. Part Description Qty.11✓ 100016 WASHER, lock 2912

Page 90 - Electrical Enclosure Parts

Parts 82 313296J★Not shown.▲Replacement Danger and Warning labels, tags, and cards are available at no cost.†Kit 24D012 only.◆Kit 24D015 only.✿Kits 24

Page 91

Parts313296J 83Warm Melt Kits for D60 SystemsKit 24D009 (CST), 24K670 (SST) with Display for D60 and D60i SystemsKit 24D010 (CST), 24K671 (SST) with D

Page 92 - Accessories

Parts 84 313296Jr_wm_2179_313296_12a258257235237236259,260,261233

Page 93 - Display Details

Parts313296J 85234262239,227228, 201, 202, 222201, 202256227229274249, 272,273223232201, 213, 240, 241ti17721a282, 283, 284

Page 94 - Navigation within Screens

Parts 86 313296JD60 Warm Melt KitsUBFB268267269270266201241276278241201265258248, 272, 273264271255201241Ref. Part Description Qty.201 100016 WA

Page 95 - Setup Mode Screens

Parts313296J 87★Not shown.▲Replacement Danger and Warning labels, tags, and cards are available at no cost.* Standard only on tandem supply systems.✿K

Page 96 - Maintenance Setup Screen

Parts 88 313296JHeated Platens - 20L, 30L, and 60L325, 326324308317318319320323311304, 305310313321309303302301307309Platen 24D066 (20L) ShownTorque t

Page 97 - Hardware Setup Screens

Parts313296J 89Parts Used on all Heated Platens▲Replacement Danger and Warning labels, tags, and cards are available at no cost.Parts that Vary by Hea

Page 98 - Advanced Setup Screens

Component Identification313296J 9Tandem Supply SystemsKey:ARam ABRam BC Air MotorD Heated Check-Mate Displacement Pump (Ram A and B)E Heated Platen (R

Page 99 - Advanced Setup Screen 3

Parts 90 313296JElectrical Enclosure Parts257158 for single supply systems and ram A of tandem supply systems257291 for ram B of tandem supply systems

Page 100 - Run Mode Screens

Parts313296J 91Electrical Enclosure Parts★Not shown.▲Replacement Danger and Warning labels, tags, and cards are available at no cost. Replacement elec

Page 101 - Heat Run Screen

Accessories 92 313296JAccessoriesPlaten Cover, 255691Two platen covers. See manual 406681 for more infor-mation for D200 platens.Two-Zone Expansion Ki

Page 102 - Icon Function

Appendix A - User Interface Display313296J 93Appendix A - User Interface DisplayDisplay OverviewThe user interface display is divided into two main fu

Page 103 - 313296J 103

Appendix A - User Interface Display 94 313296JStatusThe current system status is displayed on the right of the menu bar. If there is an error, an even

Page 104 - Dimensions

Appendix A - User Interface Display313296J 95Setup Mode ScreensSetup mode screens are divided into six sections: pass-word, system setup, heat zone se

Page 105 - D60 Models

Appendix A - User Interface Display 96 313296JNOTE: Must exit edit mode to scroll through the heat zones.Maintenance Setup ScreenThe Maintenance Setup

Page 106 - Technical Data

Appendix A - User Interface Display313296J 97Hardware Setup ScreensThe Hardware Setup screens enable users to specify if specific hardware is installe

Page 107 - 313296J 107

Appendix A - User Interface Display 98 313296JAdvanced Setup ScreensThe Advanced Setup screens enable users to set units, adjust values, set formats,

Page 108 - Graco Information

Appendix A - User Interface Display313296J 99Advanced Setup Screen 3This screen enables users to set the date, time, and date format.Advanced Setup Sc

Comments to this Manuals

No comments