313386DENSoftware InstructionsProMix® 2KS/3KS Web Interfaces Installation and program setup instructions to allow communication between a PC and the P
ProMix 2KS/3KS Basic Web Interface (BWI) 10 313386DReportsNOTE: Display material usage report - shows the material sprayed from the ProMix 2KS/3KS. Se
ProMix 2KS/3KS Basic Web Interface (BWI)313386D 11Display job log - displays the job number, date, time, recipe, ratio, target, volumes, grand totals,
Install the Advanced Web Interface (AWI) Module 12 313386DInstall the Advanced Web Interface (AWI) ModuleOverviewThe Graco Advanced Web Interface (AWI
Install the Advanced Web Interface (AWI) Module313386D 13Connect Module to EasyKey and PC1. Shut off ProMix 2KS/3KS power (0 position). FIG. 23. Also
Install the Advanced Web Interface (AWI) Module 14 313386DFIG. 25: ProMix Network Typical InstallationTI13065aEasyKeysAWI Master ModuleComputerUse CAT
Install the Advanced Web Interface (AWI) Module313386D 15FIG. 26: LAN Network (Manual) Typical InstallationTI13064bEasyKey EasyKeyLAN NetworkAWI Modul
Computer Configuration 16 313386DComputer ConfigurationSet up an Automatic IP AddressSee FIG. 27. On your computer, go to Control Panel>Network Con
Computer Configuration313386D 174. The Welcome screen will appear. See FIG. 29. Click Next.5. The Security screen will appear. See FIG. 30. The admini
Computer Configuration 18 313386DPassword Recovery1. If you type in the wrong password, sign in will be blocked. See FIG. 33. Click on the block icon
Computer Configuration313386D 19Set the Network ConfigurationProMix 2KS/3KS Network ConfigurationIn a ProMix 2KS/3KS network, the AWI module is con-ne
Related Manuals 2 313386DContentsRelated Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Warnings . . . . . . . . . . . . . . . . .
Computer Configuration 20 313386DLAN Network (Manual) ConfigurationSee FIG. 26. A LAN network (manual) configuration enables you to work through a loc
AWI Screens313386D 21AWI ScreensThis section describes how to use the AWI screens to access and make changes to system settings and reci-pes. For comp
AWI Screens 22 313386DMaterials TabUse the Materials tab to enter information on Volatile Components (VOC) and Hazardous Air Pollutants (HAP) for each
AWI Screens313386D 23
AWI Screens 24 313386DSettings TabUse the Settings tab to configure the main system set-tings (Time, Language, Upgrade AWI, and Edit Accounts). NOTE:
AWI Screens313386D 25Edit Account InformationNOTE: Account information can only be entered by a system administrator. See FIG. 42.• To add a new accou
AWI Screens 26 313386DSystem Setup ScreensTo view the system setup screens, go to the Network tab and click on the desired EasyKey to access the setup
AWI Screens313386D 27Material Setup TabGo to the Material Setup tab to assign a catalyst, color, reducer (on 3KS) and flush material for the valves of
AWI Screens 28 313386DSystem Setup TabThe Setup tab has three editable screens:•The Configuration screen corresponds to the Sys-tem Configuration scre
AWI Screens313386D 29FIG. 47. System Setup Tab, Advanced ScreenFIG. 48. System Setup Tab, Recipe ScreenClick to create a recipe timing chart. See FIG.
Warnings313386D 3WarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point s
AWI Screens 30 313386DFIG. 49. Sample Recipe Timing Chart
AWI Screens313386D 31Reports TabThe Reports tab enables you to produce three reports:• Material Report•Job Report• Alarm ReportSelect which of the thr
AWI Screens 32 313386DJob ReportSee FIG. 51. The Job Report provides detailed informa-tion on all completed jobs within a designated time period. Sele
AWI Screens313386D 33Alarm ReportSee FIG. 52. The Alarm Report lists all alarms triggered within a designated time period. Set the time frame by using
AWI Screens 34 313386DLevel Control TabSee FIG. 53. The Level Control Tab allows you to input the supply tank volume of the materials and the level at
AWI Screens313386D 35SidebarSee FIG. 54. The Sidebar relates to the EasyKey being monitored. It has four links to related screens: • Save - saves the
Replace AWI Board 36 313386DReplace AWI Board1. Shut off ProMix 2KS/3KS power (0 position). 2. Shut off power at main circuit breaker.3. Open the AWI
Replace AWI Board313386D 37
Parts 38 313386DParts15V337 Advanced Web Interface ModuleParts labeled n/a are not available separately.TI12926aTI12927aTI12928a3456810111213415171817
Parts313386D 3915V336 Advanced Web Interface Server HubParts labeled n/a are not available separately.+24COMV1+V1-TI13204aTI13206aTI13205a345681011121
ProMix 2KS/3KS Basic Web Interface (BWI) 4 313386DProMix 2KS/3KS Basic Web Interface (BWI)NOTE: Screen views in this manual are shown using Microsoft
Electrical Schematic 40 313386DElectrical SchematicNon-Hazardous AreaDISPLAYBOARD 1234 J91234567891011J41234567891011121314151617181920DISPLAYMEMBRANE
Dimensions313386D 41DimensionsTI12825b16.57 in. (420.9 mm)15.07 in. (382.8 mm)6.45 in. (163.8 mm)5.31in. (134.9 mm)8.71in. (221.2 mm)TI12926a
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th
ProMix 2KS/3KS Basic Web Interface (BWI)313386D 53. Before running the BWI software you must manually assign an IP address to your computer:a. On your
ProMix 2KS/3KS Basic Web Interface (BWI) 6 313386Dc. In the Local Area Connection Properties win-dow, scroll to Internet Protocol (TCP/IP) and double
ProMix 2KS/3KS Basic Web Interface (BWI)313386D 74. On the EasyKey, go to System Configuration Screen 5 and write down the IP number assigned to that
ProMix 2KS/3KS Basic Web Interface (BWI) 8 313386DWeb Navigation ScreensFrom the main BWI screen (see FIG. 7) the operator can select Setup, Software/
ProMix 2KS/3KS Basic Web Interface (BWI)313386D 9Download custom language - saves the current system language to the PC. See FIG. 10. This file is ope
Comments to this Manuals