Troubleshootin
g
Visual Checks
First, check the system for any visible faults or errors
to help isolate whether the spray gun, fluid hose or
voltage isolation system has failed. A voltage probe
and meter, part no. 245277, is helpful for diagnosing
voltage problems and is required for some of the
troubleshooting tests that follow.
1. Check that al
l of the air and fluid tubes and hoses
are properly
connected.
2. Check that t
he voltage isolation system valves
and control
s are properly set for operation.
3. Check that t
he interior of the isolated enclosure
is clean.
4. Check that
the spray gun and voltage isolation
system hav
e sufficient air pressure.
5. Check that
the gun ES ON/OFF valve is in the
ON positi
on and that the gun ES indicator light
is on. If t
he ES indicator light is not on, remove
the spray
gunforserviceandcompletethe
Electric
al Tests, page 36.
6. Check th
at the voltage isolation system's
enclosu
re door is closed and that any safety
interlo
cks are engaged and working properly.
7. Make sure the voltage isolation system is in
the “isolate” mode, where it is isolating the fluid
voltage from ground.
8. To eliminate air gaps in the fluid column, spray
enough fluid to purge the air out between the
voltage isolation system and the spray gun. An
air gap in the fluid hose can break the electrical
continuity between the spray gun and the isolated
fluid supply and cause a low voltage reading on
a voltage meter connected to the isolated fluid
supply.
9. Check the spray gun cover and barrel for
accumulated overspray. Excessive overspray
can create a conductive path back to the
grounded gun handle. Install a new gun cover
and clean the exterior of the gun.
10. Inspect the entire system for any visible fluid
leakage and repair any fluid leaks that are found.
Pay special attention to the following areas:
•Packinga
rea of the spray gun.
Fluid hos
e: check for leakage or any bulges in
the outer
cover, which may indicate an internal
leak.
Interna
l voltage isolation system components
3A2497B
41
Page view 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 77 78

Comments to this Manuals