Installation
309643B 3
Metal Fluid Section Pumps
Disassembly of Inlet and Outlet Manifolds
1. Relieve the pressure, see page 2. Disconnect all
hoses.
2. Remove the pump from its mounting.
3. Remove the bolts (106) holding the outlet manifold
(103) to the fluid covers (101). See F
IG
. 1.
4. Remove the o-rings (202, not used on some mod-
els), seats (201), and balls (301) from manifold
(103).
5. Turn the pump over and remove the inlet manifold
(102). Remove the o-rings (202, not used on some
models), seats (201), and balls (301) from fluid cov-
ers (101).
F
IG
. 1
1
2
3
4
Apply medium-strength (blue) Loctite or equivalent to
the threads, and torque to 120-150 in-lb (14-17 N.m).
Arrow (A) must point toward outlet manifold (103).
Beveled seating surface must face the ball (301).
Not used on some models.
1040 Model Shown
106
103
1
301
201
202
101
3
A
2
301
201
202