Graco 312877P User Manual

Browse online or download User Manual for Unknown Graco 312877P. Graco 312877P User's Manual [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Operation
Husky
®
1050 Air-Operated
Diaphragm Pump
312877P
EN
1-inch pump with modular air valve for fluid transfer applications.
For professional use only.
See page 4 for model information, including approvals.
125 psi (0.86 MPa, 8.6 bar) Maximum Fluid Working Pressure
125 psi (0.86 MPa, 8.6 bar) Maximum Air Input Pressure
End
Flange
Center
Flange
ti13843a
1050P Polypropylene
1050C Conductive
Polypropylene
1050F PVDF
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
1050A Aluminum
ti13946ati14342a
1050S Stainless Steel
1050H Hastelloy
ti13844a
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Diaphragm Pump

OperationHusky® 1050 Air-OperatedDiaphragm Pump312877PEN1-inch pump with modular air valve for fluid transfer applications.For professional use only.S

Page 2 - Related Manuals

Installation 10 312877PAir Exhaust VentilationThe air exhaust port is 3/4 npt(f). Do not restrict the air exhaust port. Excessive exhaust restriction

Page 3 - Distributor Note

Installation312877P 11Fluid Supply LineSee FIG. 4, page 12.1. Use grounded, flexible fluid supply lines (G). See Grounding, page 8.2. If the inlet flu

Page 4 - Configuration Number Matrix

Installation 12 312877PKey for FIG. 4:A Air supply lineB Bleed-type master air valve (required for pump)C Air filter/regulator assemblyD Air inletE Ma

Page 5 - Warnings

Installation312877P 13Fluid Inlet and Outlet PortsNOTE: Remove and reverse the manifold(s) to change the orientation of inlet or outlet port(s). Follo

Page 6 - 6 312877P

Installation 14 312877PFluid Pressure Relief ValveFIG. 6. Fluid pressure relief kit (Aluminum pumps only, 1050A models)Some systems may require instal

Page 7 - Installation

Operation312877P 15OperationPressure Relief Procedure1. Shut off the air supply to the pump.2. Open the dispensing valve, if used.3. Open the fluid dr

Page 8 - Grounding

Maintenance 16 312877P10.If you are flushing, run the pump long enough to thoroughly clean the pump and hoses.11.Close the dispensing valve, if used.1

Page 9 - Reed Switch

Maintenance312877P 17Torque InstructionsNOTE: Fluid cover and manifold fasteners have a thread-locking adhesive patch applied to the threads. If this

Page 10 - Air Exhaust Ventilation

Dimensions and Mounting 18 312877PDimensions and MountingAluminum (1050A)5.0 in.5.5 in.(140 mm)(127 mm)KJH&%EA103/GFDti12212b ti12211bti12213bti14

Page 11 - Fluid Outlet Line

Dimensions and Mounting312877P 19Polypropylene (1050P), Conductive Polypropylene (1050C)and PVDF (1050F)NOTE: Listed dimensions are accurate for both

Page 12 - Key for FIG. 4:

Related Manuals 2 312877PContentsRelated Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2To Find Your Nearest Distributor . . . . .

Page 13 - Fluid Inlet and Outlet Ports

Dimensions and Mounting 20 312877PHastelloy (1050H) and Stainless Steel (1050S)&(%$103*'/.-+LQPPLQPPti14343b ti14344bti

Page 14 - Fluid Pressure Relief Valve

Performance Charts312877P 21Performance ChartsTest Conditions: Pump tested in water with inlet submerged.051015 20 2530 35 4045 50(19) (38)(57) (76) (

Page 15 - Operation

Technical Data 22 312877PTechnical DataMaximum fluid working pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 psi (0.86

Page 16 - Maintenance

Technical Data312877P 23* Sound power measured per ISO-9614-2.** Sound pressure was tested 3.28 ft (1 m) from equipment.All trademarks mentioned in th

Page 17 - Torque Instructions

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Page 18 - Dimensions and Mounting

To Find Your Nearest Distributor312877P 3To Find Your Nearest Distributor1. Visit www.graco.com.2. Click on Where to Buy and use the Distributor Locat

Page 19 - 312877P 19

Configuration Number Matrix 4 312877PConfiguration Number MatrixCheck the identification plate (ID) for the 20-digit Configuration Number of your pump

Page 20 - 20 312877P

ATEX Certifications312877P 5ATEX CertificationsWarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equip

Page 21 - Performance Charts

Warnings 6 312877PSPECIAL CONDITIONS FOR SAFE USEEquipment must comply with the following conditions to avoid a hazardous condition which can cause fi

Page 22 - Technical Data

Installation312877P 7InstallationThe Typical Installation shown in FIG. 4 is only a guide for selecting and installing system components. Contact your

Page 23 - Fluid Temperature Range

Installation 8 312877PMounting1. For wall mounting, order Graco Kit 24C637.2. Be sure the mounting surface can support the weight of the pump, hoses,

Page 24 - Graco Information

Installation312877P 9Check your system electrical continuity after the initial installation, and then set up a regular schedule for checking continuit

Comments to this Manuals