Pressure Relief Procedure
10 3A2264A
Grounding
The equipment must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for the electrical current due to static build
up or in the event of a short circuit.
Pump: use g
round wire and clamp (supplied). Loosen
grounding lug locknut and washer. Insert ground wire
end into lug slot and tighten locknut securely. Connect
ground clamp to a true earth ground.
Air and fluid hoses: use on
ly electrically conductive
hoses with a maximum of 500 ft. (150 m) combined
hose length to ensure grounding continuity. Check elec-
trical resistance of hoses. If to
tal resistance to ground
exceeds 29 megohms, replace hose immediately.
Air compressor:
follow manufacturer’s recommenda-
tions.
Dispense valve: g
round through connection to a prop-
erly grounded fluid hose and pump.
Fluid supply container: f
ollow local code.
Solvent pails used when flushing: f
ollow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a nonconductive sur-
face, such as paper or cardboard, which interrupts
g
rounding continuity.
To maintain grounding continuity when flushing or
re
lieving pressure: hold metal part of the dispense
valve firmly to the side of a grounded metal pail, then
trigger the valve.
Pressure Relief
Procedure
NOTE: Refer to FIG. 2 on page 8 for the following proce-
dure.
1. Turn off the air motor slider valve (BF) on both ram A
an
d B.
2. On both ram A and B, turn off the main air slider
valve (BA). Set the ram director valve (BC) to the
down position. The ram will slowly drop.
3. Perform Pressure Relief Procedure of the HFR
system. See manual 3A2175.
4. On both ram A and B, open the drain valve and/or
the pump bleed port. Have a container ready to
catch the drainage.
If you suspect that the spray tip/nozzle or hose is com-
pletely clogged, or that pressure has not been fully
relie
ved after following the steps above, very slowly
loosen the tip guard retaining nut or hose end coupling
and relieve pressure gradually, then loosen completely.
Now clear the tip/nozzle or hose.