PROCESS EQUIPMENT CATALOG
Technical Specifications
Husky 205 Plastic Pumps
Air-Operated Double Diaphragm
Husky 205 Plastic Pumps Acetal Polypropylene PVDF
Maximum fluid working pressure 100 psi (7 bar, 0.7 MPa) 100 psi (7 bar, 0.7 MPa) 100 psi (7 bar, 0.7 MPa)
Maximum free flow delivery* 5.0 gpm (18.9 lpm) 5.0 gpm (18.9 lpm) 5.0 gpm (18.9 lpm)
Maximum pump speed 250 cpm 250 cpm 250 cpm
Displacement per cycle** 0.012 gallon (0.045 liter) 0.012 gallon (0.045 liter) 0.012 gallon (0.045 liter)
Maximum suction lift (D12096) 10 ft (3 m) dry 10 ft (3 m) dry 10 ft (3 m) dry
Maximum size pumpable solids 0.06 in (1.5 mm) 0.06 in (1.5 mm) 0.06 in (1.5 mm)
Maximum ambient operating temperature*** 180°F (82°C) 150°F (66°C) 180°F (82°C)
Maximum diaphragm operating temperature*** Refer to page 5 Refer to page 5 Refer to page 5
Typical sound level at 70 psi
(4.9 bar, 0.49 MPa) air @ 125 cpm
70 dBa 70 dBa 70 dBa
Maximum air consumption 9.0 scfm (0.252 m3/min) 9.0 scfm (0.252 m3/min) 9.0 scfm (0.252 m3/min)
Air pressure operating range 20 to 100 psi
(1.4 to 7 bar, 0.14 to 0.7 MPa)
20 to 100 psi
(1.4 to 7 bar, 0.14 to 0.7 MPa)
20 to 100 psi
(1.4 to 7 bar, 0.14 to 0.7 MPa)
Air inlet size 1/4 npt(f) 1/4 npt(f) 1/4 npt(f)
Air exhaust port size 1/4 npt(f) 1/4 npt(f) 1/4 npt(f)
Fluid inlet & outlet size**** 1/4 npt(f) 1/4 npt(f) 1/4 npt(f)
Weight 2.5 lb (1.1 kg) 2.0 lb (0.9 kg) 2.8 lb (1.3 kg)
Wetted parts
(in addition to ball, seat and diaphragm
materials– which may vary by pump)
Acetal with Stainless Steel fibers,
PTFE, Acetal, Santoprene
Glass-filled Polypropylene,
Santoprene, PTFE, Polypropylene
PVDF, PTFE, Santoprene
Instruction manual 308652 308652 308652
** Displacement per cycle may vary based on suction condition, discharge head, air pressure and fluid type
*** Actual pump performance may be affected by prolonged usage at temperature
**** Hybrid thread allows for either 1/4 npt or 1/4 bspt fitting
Wall bracket
standard
with pump
Performance Charts
C
FLUID FLOW
(Pump tested in water with inlet submerged
FLUID OUTLET PRESSURE psi (bar, MPa)
AIR CONSUMPTION scfm (m
3
/min)
gpm
(lpm)
0.5
(1.9)
120
(8, 0.8)
100
(7, 0.7)
80
(5.5, 0.55)
60
(4.1, 0.41)
40
(2.8, 0.28)
20
(1.4, 0.14)
0
1
(3.8)
1.5
(3.8)
2
(7.6)
2.5
(9.5)
3
(11.4)
3.5
(13.3)
0
B
A
B
C
A
Husky 205 Performance
AIR PRESSURE LEGEND
= at 100 psi (7 bar, 0.7 MPa) Air Consumption
= at 70 psi (4.8 bar, 0.48 MPa) Fluid Pressure
= at 40 psi (2.8 bar, 0.28 MPa)
A
B
C
1
(0.028)
2
(0.057)
3
(0.085)
4
(0.11)
5
(0.14)
6
(0.17)
updated 2/15