Graco Husky 515 User Manual

Browse online or download User Manual for Unknown Graco Husky 515. Graco Husky 515 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Husky 515 Plastic Pumps
Air-Operated Double Diaphragm
PROCESS EQUIPMENT CATALOG
Popular Models
PROCESS EQUIPMENT CATALOG
Performance Charts
Technical Specifications
Husky 515 Plastic Pumps Acetal Polypropylene PVDF
Maximum fluid working pressure 100 psi (7 bar, 0.7 MPa) 100 psi (7 bar, 0.7 MPa) 100 psi (7 bar, 0.7 MPa)
Maximum free flow delivery* 15 gpm (57 lpm) 15 gpm (57 lpm) 15 gpm (57 lpm)
Maximum pump speed 400 cpm 400 cpm 400 cpm
Displacement per cycle** 0.04 gallon (0.15 liter) 0.04 gallon (0.15 liter) 0.04 gallon (0.15 liter)
Maximum suction lift *** 15 ft (4.5 m) dry 15 ft (4.5 m) dry 15 ft (4.5 m) dry
Maximum size pumpable solids 0.09 in (2.5 mm) 0.09 in (2.5 mm) 0.09 in (2.5 mm)
Maximum ambient operating temperature† 180°F (82°C) 150°F (66°C) 180°F (82°C)
Maximum diaphragm operating temperature† Refer to page 5 Refer to page 5 Refer to page 5
Typical sound level at 70 psi
(4.9 bar, 0.49 MPa) air @ 125 cpm
74 dBa 74 dBa 74 dBa
Maximum air consumption 28 scfm (0.672 m3/min) 28 scfm (0.672 m3/min) 28 scfm (0.672 m3/min)
Air pressure operating range 30 to 100 psi
(2.1 to 7 bar, 0.21 to 0.7 MPa)
30 to 100 psi
(2.1 to 7 bar, 0.21 to 0.7 MPa)
30 to 100 psi
(2.1 to 7 bar, 0.21 to 0.7 MPa)
Air inlet size 1/4 npt(f) 1/4 npt(f) 1/4 npt(f)
Air exhaust port size 3/8 npt(f) 3/8 npt(f) 3/8 npt(f)
Fluid inlet & outlet size**** 1/2 npt(f) or bspt(f) 1/2 npt(f) or bspt(f) 1/2 npt(f) or bspt(f)
Weight 7.8 lb (3.5 kg) 6.5 lb (2.9 kg) 8.5 lb (3.9 kg)
Wetted parts
(in addition to ball, seat and diaphragm materials–
which may vary by pump)
Groundable Acetal, PTFE, SST Polypropylene, PTFE, SST PVDF, PTFE
Instruction manual 308981 308981 308981
* Flow rates are with muffler and do not vary based on diaphragm material.
** Displacement per cycle may vary based on suction condition, discharge head, air pressure and fluid type
*** Duckbill suction lift 11 ft (3.3 m)
**** Hybrid thread allows for either 1/4 npt or 1/4 bspt fitting
† Actual pump performance may be affected by prolonged usage at temperature.
FLUID FLOW
(Pump tested in water with inlet submerged
FLUID OUTLET PRESSURE psi (bar, MPa)
AIR CONSUMPTION scfm (m
3
/min)
gpm
(lpm)
80
(5.5, 0.55)
100
(7, 0.7)
60
(4.1, 0.41)
40
(2.8, 0.28)
20
(1.4, 0.14)
6
(0.17)
12
(0.37)
18
(0.50)
24
(0.67)
30
(0.84)
0
4
(15.2)
8
(30)
12
(45.42)
16
(60.56)
0
Husky 515 Performance
AIR PRESSURE LEGEND
= at 100 psi (7 bar, 0.7 MPa) Air Consumption
= at 70 psi (4.8 bar, 0.48 MPa) Fluid Pressure
= at 40 psi (2.8 bar, 0.28 MPa)
A
B
C
= at 20 psi (1.4 bar, 0.14 MPa)
D
A
B
C
D
D
C
B
A
updated 2/15
Page view 0
1

Summary of Contents

Page 1 - Husky 515 Plastic Pumps

Husky 515 Plastic PumpsAir-Operated Double Diaphragm PROCESS EQUIPMENT CATALOGPopular ModelsPROCESS EQUIPMENT CATALOGPerformance ChartsTechnical Speci

Comments to this Manuals

No comments