Graco 17A226 Use and Care Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
Cleanup
333394E 13
Cleanup
Pressure Relief Procedure
Follow the Pressure Relief Proce-
dure whenever you see this symbol.
1. Disconnect power (unplug power cord).
2. Turn Prime Pump/Spray Knob down to
PRIME PUMP position to relieve pres-
sure.
Cleaning Sprayer
Cleaning your sprayer properly and after every
spray job is of the utmost importance! Proper
care and maintenance will make your paint
sprayer last and work for you trouble free.
1. Turn Prime Pump/Spray knob to Prime
Pump to relieve pressure.
2. Separate the cup support with FlexLiner
from the cup cover/sprayer.
Use only water-based or oil-based
(mineral spirit-type) materials with flash
point greater than 100° F (38° C).
Do not
use materials which state “FLAMMABLE”
on the packaging. For more information
about your material, request MSDS from
distributor or retailer.
Clean in a well-ventilated area.
Keep a
good supply of fresh air moving through the
area.
To avoid serious injury or damage to
equipment, do not expose the sprayer
electronics to cleaning fluids. Keep sprayer
at least 10 in. (25 cm)
above the rim of the
container when cleaning.
This sprayer builds up an internal
pressure of 2000 psi (14 MPa, 138 bar)
during use. Follow this
Pressure Relief
Procedure
whenever you stop spraying
and before cleaning, checking, servicing,
or transporting equipment to prevent
serious injury.
ti23408a
ti23285a
Prime Pump
ti23385a
Page view 12