Operation
6 312147B
Operation
Oil Level
When necessary, completely fill the lubricator reservoir
with clean filtered lubricant. A sight level gauge is pro-
vided on the reservoir to monitor the fluid level. Oil level
should not be allowed to drop below the line indicating
an empty reservoir.
During the initial filling, remove the vent plug from
pumps using sight glasses prior to filling the reservoir.
This allows lubricant to rise in the vacuum tube up to the
level of lubricant in the reservoir and reduces the prim-
ing required at start up.
Pump Priming
If the sight well on the pump does not contain oil, the
pump should be primed using the following procedure:
1. If using a vacuum type pump with a sight glass,
remove the vent screw located on the top of the
sight glass.
2. Adjust the pump stroke length to its maximum set-
ting.
3. Depress the hand plunger assembly and release
when the cap contacts the adjustment rod guide.
4. Repeat until an air free stream of fluid exits the
pump outlet.
5. Replace the vent screw at the top of the sight glass.
Pumping Rate
The amount of lubricant dispensed from each pump can
be adjusted. The volume dispensed by each pump is
indicated by the amount of lubricant dripping from the
vacuum tube inside the sight glass.
The amount of dispensed volume can be adjusted by
performing the following steps:
1. Loosen the adjustment rod lock nut.
2. Turn the adjustment rod guide clockwise to
decrease the amount of lubricant dispensed, or
counterclockwise to increase the amount of lubri-
cant dispensed.
3. Once the desired settings have been achieved,
tighten the adjustment rod lock nut by hand.
.
If pressurized pumps are used, the reservoir should
be filled with lubricant to extend the life of the inter-
nally moving components.
The vacuum tube dispense rate is accurate after
the pump has operated long enough to stabilize
the pressure inside the sight glass. There is a time
lag at start-up, low dispense rates, and during the
adjustment of dispense rates. Allow sufficient time
to ensure the proper amount of lubricant is dis-
pensed.