Technical Data
8 312147B
Other servicing that may be required is listed below:
Periodic cleaning of the lubricator is desirable to
eliminate contamination that may have occurred in
the oil. To accomplish this, remove all pumping units
and clean the pumps and reservoir by brushing
loose all foreign matter, dipping in solvent and blow-
ing dry with compressed air.
If external leakage is observed, determine the
cause (loose bolts, defective gaskets, or seals) and
repair as required.
Technical Data
*Varies with pump selection, see Models chart on page 4.
Plunger diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/16 in. (4.8 mm) for Models 76B and 88B
3/8 in. (9.5 mm) for Models 76E and 88E
1/4 in. (6.4 mm) for Models 76C and 88C
Maximum Working Pressure*. . . . . . . . . . . . . . . . . . . . . . 2500-7500 psi (17.5-52.5 MPa; 175-525 bar)
Minimum Pump Dispensing Rate* . . . . . . . . . . . . . . . . . . 0.002 - 0.008 cu. in.
Maximum Pump Dispensing Rate* . . . . . . . . . . . . . . . . . 0.013 - 0.055 cu. in.
Operating Temperature Range. . . . . . . . . . . . . . . . . . . . . -20°F to 140°F (-29°C to 60°C)
Dispensing Fluid Viscosity . . . . . . . . . . . . . . . . . . . . . . . . 100 - 5000 SUS
Wetted Materials music wire, carbon steel, nylon, aluminum, nitrile rubber