332511A
EN
Kit Instructions
ExactaBlend
AGP Advanced Glazing Proportioner
Heated Platen Kit
For heating bulk supply of medium to high viscosity polysulfide and urethane materials.
For professional use only.
Not approved for use in explosive atmospheres or hazardous locations.
24R200
Heated platen kit, high volume
Refer to ExactaBlend AGP Advanced Glazing Proportioner, Setup-Operation manual for maximum working pressure
and model information.
Important Safety Instructions
Read all warnings and instructions in this
manual and the ExactaBlend AGP Advanced
Glazing Proportioner, Setup-Operation man-
ual. Save all instructions.
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Heated Platen Kit

332511AENKit InstructionsExactaBlend™ AGP Advanced Glazing ProportionerHeated Platen KitFor heating bulk supply of medium to high viscosity polysulfid

Page 2 - Contents

Installation 10 332511A7. Mount the Junction Box.a. Mount the junction box to the air motor located on the 55 gallon (208 liter) ram.b. Route the cond

Page 3 - WARNINGWARNINGWARNING

Installation332511A 119. Route the Power Cord and Signal Cable to the Junction Box.Secure the power cord and signal cable to the base (A) cross bar.10

Page 4 - Component Identification

Installation 12 332511A11.Connect the Power Cable from the Heat Electrical Enclosure to the Main Electrical Enclosure.12.Connect Power to the Terminal

Page 5 - Heat Controller

Setup332511A 13Setup1. Turn the power on at the heated platen electrical enclosure.2. Turn the power on at the heater power switch.3. Set the desired

Page 6

Operation 14 332511AOperationStartup1. Turn the power on at the heated platen electrical enclosure.2. Turn the power on at the heater power switch.3.

Page 7 - 3. Connect the Ground Wires

Maintenance332511A 15MaintenancePlaten MaintenanceIf the platen does not come out of the pail easily when the pump is being raised, the air assist tub

Page 8 - 5. Mount the RTD

Troubleshooting 16 332511ATroubleshootingBefore performing any troubleshooting procedure:1. Perform Pressure Relief Procedure In the Exact-aBlend AGP

Page 9 - 6. Attach the Platen Covers

Troubleshooting332511A 17No heat. Tripped circuit breaker. Visually check circuit breaker for a tripped condi-tion.Determine cause of tripped circuit

Page 10 - 7. Mount the Junction Box

Repair 18 332511ARepairReplace Platen Heaters and Sensor55 Gallon Platen Heater and Sensor1. Turn off main disconnect at the machine.2. Allow equipmen

Page 11 - 332511A 11

Schematic332511A 19Schematic14014914714514211013813613413213012812612412212011811411611210810610410210014114814414614311113913713513313112912712512312

Page 12 - 12 332511A

Related Manuals 2 332511ARelated ManualsRefer to ExactaBlend AGP Advanced Glazing Propor-tioner, Setup-Operation manual for the complete list of relat

Page 13 - 332511A 13

Parts 20 332511APartsHeated Platen Kit, 24R200FIG. 5: Heated Platen Kit14115,266223522232811714

Page 14 - Operation

Parts332511A 21FIG. 6: Heated Platen Kit18212536301916,454271783233343524810313944434042373841404344

Page 15 - Maintenance

Parts 22 332511ARef Part Description Quantity1 --- FERRULE, wire, 14awg 22 --- FASTENER, platen, cover 23 --- COUPLER, conduit 24 --- ENCLOSURE, plate

Page 16 - Troubleshooting

Parts332511A 23▲ Replacement Danger and Warning labels, tags and cards are available at no cost.--- Not available for individual sale.37 --- BRACKET,

Page 17 - 332511A 17

Parts 24 332511AHeat Enclosure, 24R870FIG. 7: Heat Module109128109109127107108110116108134132106136111101,112,113

Page 18 - Replace Platen Heaters and

Parts332511A 25FIG. 8: Heat Module102,104114,115122121119124118120125123122129118130130131139130117102,103126

Page 19 - Schematic

Parts 26 332511A▲ Replacement Danger and Warning labels, tags and cards are available at no cost.--- Not available for individual sale.Ref Part Descri

Page 21 - 332511A 21

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Page 22 - 22 332511A

Warnings332511A 3WarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point s

Page 23 - 332511A 23

Component Identification 4 332511AComponent IdentificationHeated Platen KitKey:A RTD Temperature SensorBHeater CoilC Temperature Limit SwitchD Junctio

Page 24 - Heat Enclosure, 24R870

Component Identification332511A 5Heat ControllerKey:AA Current TemperatureAB Power is Supplied to HeaterAC Power is Supplied to Heat Overtemp Contacto

Page 25 - 332511A 25

Installation 6 332511AInstallationGroundingGround the system as instructed within this manual.1. Access the Platena. Perform Change Drums procedure in

Page 26 - 26 332511A

Installation332511A 72. Install the Heat Coils and the Thermostat Switch.3. Connect the Ground Wires.Connect the ground wires to the terminal lug and

Page 27 - 332511A 27

Installation 8 332511A4. Connect the Power Leads.Label “A” and “B” leads for identification in step 10. Route all the wires through the conduit when c

Page 28 - Graco Information

Installation332511A 96. Attach the Platen Covers.NOTE: Torque the platen cover fasteners to 60 +/- 10 in-lbs (6.8 +/- 1.1 N•m).NOTICETo prevent damage