Setup - PartsHFRS Tandem Supply System KitFor use with non-heated bulk supply of medium to high viscosity sealants and adhesive materials. For profess
Pressure Relief Procedure 10 3A2264AGroundingThe equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an e
Startup3A2264A 11StartupFlush Before Using EquipmentThe pump was tested with lightweight oil, which is left in the fluid passages to protect parts. To
Shutdown 12 3A2264AShutdownThe tandem supply controls do not effect essential sys-tem operation.The tandem controls act to allow only one of the two p
Troubleshooting3A2264A 13TroubleshootingNOTE: Refer to the Supply System Repair-Parts manual for specific ram troubleshooting. Refer to the Check-Mate
Repair 14 3A2264ARepairRam RepairSee manual 313527 for ram and platen repair proce-dures and replacement parts.Pump RepairSee pump manuals for pump re
Schematics3A2264A 15SchematicsPneumatic Crossover315241(IN)2(EX)3(CYL)REMOTEPILOTINEXABRAM ALEVEL SWITCHINTEGRATEDAIR CONTROLESTCODERAM APUMP315241(IN
Schematics 16 3A2264AD200 Ram Tube Connection DiagramTagTube Size(in.)Lengthin (mm) FunctionA1 1/4 36 (914) Pilot air to switch on Unit A air motorA2
Schematics3A2264A 17S20 Ram Tube Connection DiagramTagTube Size(in.)Lengthin (mm) FunctionA1 1/4 61 (1550) Pilot air to switch on Unit A air motorA2 1
Parts 18 3A2264APartsTandem Supply System - D200Supply System ASupply System B002001002005,005,004007006008 (2x)009 (2x)006006003003003003
Parts3A2264A 19Ref Part DescriptionQuantity24M226, KIT, upgrade, 20:1, pxover, 55 gallon, carbon24M227, KIT, upgrade, 20:1, pxover, 55 gallon, stainle
2 3A2264AContentsRelated Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Models . . . . . . . . . . . . . . . . . . . . . . . . .
Parts 20 3A2264ATandem Supply System - S20Supply System ASupply System B002001002005,005,004007006008 (2x)009 (2x)006006003003
Parts3A2264A 21Ref Part DescriptionQuantity24M228, KIT, upgrade, 20:1, pxover, 5 gallon, carbon24M229, KIT, upgrade, 20:1, pxover, 5 gallon, stainless
Parts 22 3A2264APneumatic Crossover Kits255675, for 3 in. D200 Rams257373 for S20 Rams201223202203206209208207205206224225226229229230225229 229222221
215 214213216221211222219217218210212220228229226226229TI10942ALevel Switch Assembly 255675r_257373_313529_1aLevel Switch Assembly 2573732152142222112
Parts 24 3A2264APneumatic Crossover Kits★ Not shown.--- Not for sale.Ref. Part Description Qty201 111337 TEE, street; 3/4 npt(m) x 3/4 npt(f) x 3/4 np
Parts3A2264A 25Pump Outlet Check Valve Kits255452, used on carbon steel Check-Mate 60 and 100 Displacement Pumps (shown)257377, used on stainless stee
Technical Data 26 3A2264ATechnical DataMax air input pressure (supply system) psi (MPa, bar) / Air inlet sizeS20 - 3 in. single post, 5 gal. (20 L). .
Technical Data3A2264A 27
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th
Related Manuals3A2264A 3Related ManualsComponent Manuals in U.S. English:Manual Description313526 Supply Systems Operation313527 Supply Systems Repair
Models 4 3A2264AModelsCheck the identification plate (ID) for the 6-digit part number of your tandem system.IDTo order replacement parts, see Parts st
Overview3A2264A 5OverviewKit DescriptionEach tandem supply kit consists of one single air-pow-ered ram supply system and supply hose, as well as all t
Overview 6 3A2264APneumatic Crossover System ComponentsNOTE: D200, and S20 sizes are used in pneumatic cross-over systems.FIG. 1. shows a pneumatic c
Overview3A2264A 7Key to FIG. 1:ARam ABRam BC Pump (Ram A and B)D Platen (Ram A and B)E Limit Switch (Ram A and B)H Integrated Air Controls (Ram A and
Overview 8 3A2264AIntegrated Air ControlsThe integrated air controls include:• Main air slider valve (BA): turns air on and off to the system. When cl
Setup3A2264A 9SetupRam Installation and Setup1. Install and set up individual rams as explained in manual provided.2. Install outlet check valve assem