Page view 92
Motor Control Module Technical Data
313998S 93
Motor Control Module Technical Data
Overtemperature protection is provided to protect from motor overload.
Current limit, set via the software, is provided as a secondary protection from motor overload.
All installations and wiring must comply with NEC and local electrical codes.
Input Specifications
Input Line Voltage ........................... 0-264 Vac, line-to-line
Input Line Phasing ........................... Single or Three Phase
Input Line Frequency ......................... 50/60 Hz
Input Current per Phase....................... 25A(three-phase), 50A (single-phase)
Maximum Branch Circuit Protection Rating: ....... 30A(three-phase), 63A (single-phase)
Short Circuit Current Rating.................... 5kA
Output Specifications
Output Line Voltage .......................... 0-264 Vac
Output Line Phasing ......................... Three Phase
Output Current .............................. 0-30A
Output Overload............................. 200% for 0.2 seconds
DC Power Supply ............................... 24Vdc,Class 2, Graco-provided power supply
Enclosure ..................................... Type1
Max Ambient Temperature ........................ 50°C (122°F)