7. If the resistance is greater than 100 ohms, check
the tightness of the ground connections and be
suretheairhosegroundwireisconnectedtoa
true earth ground. If the resistance is still too
high, replace the air hose.
8. Using an ohmmeter (AA) measure the resistance
between the cabinet ground lug (214) and a true
earth ground (CC). The resistance must be less
than 100 ohms.
Figur
e 15 Check Cabinet Grounding
Flush Before Using Equipment
The e
quipment was tested in fluid at the factory. To
avoi
d contaminating your fluid, flush the equipment
with
a compatible solvent before using the equipment.