Graco 3A2497BPro User Manual Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 78
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
Maintenance
Maintenance
Flushing
•Flushbefore
changing fluids, before fluid can dry
in the equipm
ent, at the end of the day, before
storing, and
before repairing equipment.
•Flushatthe
lowest pressure possible. Check
connectors
for leaks and tighten as necessary.
•Flushwitha
non-flammable solvent that is
compatible
with the fluid being dispensed and the
equipment
wetted parts.
To reduce the risk of fire, explosion, or electric
shock, turn OFF (O) the ES On-Off switch before
flushing the gun.
Follow the Fluid Voltage Discharge and Grounding
Procedure, page 25, before flushing.
Only flush, purge, or clean the gun with fluids that
meet the following flammability requirements:
FM, FMc Approved:
Material does not sustain burning in accordance
with the Standard Test Method for Sustained
Burning of Liquid Mixtures, ASTM D4206.
CE-EN 50059 Compliant:
Materials which cannot be ignited, in any mixture
with air, by an energy source of less than 500mJ.
NOTICE
Only use non-flammable solvents when flushing
or cleaning equipment.
1. Turn OFF (O) t
he ES On-Off switch. Wait 30
seconds for t
he voltage to bleed off.
2. Discharge the system voltage. See Fluid Voltage
Discharge and Grounding Procedure, page 25.
3. Follow the Pressure Relief Procedure, page 26.
4. Removeandcleantheaircapandspraytip.
5. Change the fluid source to non-flammable
solvent.
6. Point the gun into a grounded metal pail. Flush
until clean solvent flows from the gun.
3A2497B 31
Page view 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 77 78

Comments to this Manuals