Graco 3A2497BPro User Manual Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 78
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
Troubleshootin
g
Problem
Cause Solution
Gun is too clos
e to the part being
sprayed.
Gun should be 8
–12 in. (200–300
mm) from the pa
rt.
Voltage/current display stays red
(smart guns only).
Dirty gun.
See Clean the Gun Daily, page 33.
ES or Hz indicator is amber.
Air turbine s
peed is too low.
Increase air
pressure until
indicator is
green. To avoid
over-atomi
zation, use the
atomizing a
ir restrictor valve to
reduce the a
tomizing air to the air
cap.
ES or Hz indicator is red.
Air turbine speed is too high. Decrease air pressure until
indicator is green.
Error display appears and Hz
indicator is red (Smart guns only).
Smart mod
ule has lost
communic
ation with the power
supply.
Check for
good connections
between S
mart Module and
power sup
ply. See Smart Module
Replacem
ent, page 58,and
Power Sup
ply Removal and
Replace
ment, page 52.
46 3A2497B