Adjusting Grease Output Volume
If a meter is not producing the correct amount of lubri-
cant for a specific location on a vehicle or if a replace-
ment meter of correct size is not available, output
spacer washers can be installed to adjust the meter’s
output volume.
Use Table 1 to determine which size meter is appropri-
ate for the grease location.
To change output volume:
1. Relieve pressure, page 15.
2. If the meter is located on a manifold, use a 7/16”
wrench to remove tubing (F
IG. 13).
3. Use a 5/8” deep well socket to remove meter from
manifold (F
IG. 14).
4. Place meter in a vise, output end (tube connector)
facing up.
5. Use two 5/8” wrenches to separate the meter
halves.
6. Separate the meter body from the valve assembly.
Be careful not to misplace or damage springs and/or
TABLE 1: Meter Identification and Usage
Meter
Size
Number of
Washers
Hex
Flat
Output
(in.
3
)
Recommendations for
Specific Lubrication Points
0
0 No 0.002 Brake Shafts, transmissions, cross shafts, “S” cams
1
1 No 0.005 Slack adjusters, 5th wheel pivot, and miscellaneous points
2
2 No 0.009 Drag link, tie rod ends, power steering linkage
3
3 No 0.012 Kin pins, spring pins, spring shackles
4
4 No 0.020 Misceallenous points
8*
4 Yes 0.026 5th Wheel plate
*Size 8 high output meters cannot
be changed.
FIG. 13
FIG. 14