Troubleshooting
16 312054J
Troubleshooting
Problem Cause Solution
Too much grease at all lube points Timer cycle too frequent Adjust the timer one click to a higher time
cycle. (Example, from 2 to 3 hours.)
Too much grease at one lube point Meter leaking Remove and replace meter
Not enough grease at all lube
points
Timer cycle is too infrequent Adjust the timer one click to a lower time
cycle. (Example, from 3 to 2 hours.)
No sign of fresh grease at all points Lubricant reservoir filled with
heavy grease which will not
work in system.
Remove and clean reservoir, refill with
proper lubricant. Remove main line plugs
from meter blocks, and cycle pump until old
lubricant is removed from lines, replace
main line plugs.
Blown fuse, or break in wiring
circuit
Check for electrical short circuit or broken
wire, and repair.
Broken air line (air pump only) Repair or replace line.
Inoperative solenoid air valve
(Air pump only)
Check electrical circuit to make sure volt-
age is reaching the solenoid coil from the
timer. Connect a meter from the supply
“black” wire to the return “white” wire at the
connector of the solenoid. Do not connect
direct to ground. Repair or replace wiring
as required: Check coil resistance for
approx. 20 ohms. Check valve operation;
repair or replace if necessary.
Inoperative air pump
See Troubleshooting, Air-operated pump
not working, page 18.
Inoperative electric pump See Troubleshooting, Electrically operated
pump not working, page 18.