Installation
6 312054J
Electric Pump Installation
NOTE: Electric Grease Jockey pumps are available with
or without a timer. Choose the appropriate installation
section.
Fuses
The following fuse information applies to all models:
Use standard automotive style blade fuses, ATO
series 257. Fuses are available from your Graco
distributor.
Never use a higher amperage capacity fuse. Dam-
age to the pump and vehicle electrical system could
occur.
Install fuse holders in a protected area, as far from
the pump as possible. This will provide maximum
protection to the vehicle electrical system.
Pump Models without a Timer
Refer to Wiring Schematic (FIG. 4) for these instructions.
1. Install 10 Amp fuse (12 VDC models) or 5 Amp fuse
(24 VDC model) in line with the White wire con-
nected to the first pole of the Hirschmann connector.
2. Wire as follows. If using a Graco mating cable, the
wire color corresponding to the 3-Pole Hirschmann
connection point is provided in parenthesis.
Chassis Ground (-) to Hirschmann connection,
labeled number 2 (Black wire)
Ignition (+) to Hirschmann connection, labeled
number 1 (White wire) - This source should only
provide a voltage supply when the vehicle igni-
tion switch is on.
NOTE: The Hirschmann connection labeled ground, or
the green wire of a Graco mating cable, is not used for
either voltage models.
Pump Models with a Timer
Refer to Wiring Schematic (FIG. 5) for these instructions.
1. Install 10 Amp fuse (12 VDC model) or 5 Amp fuse
(24 VDC model) in line with the wire connected to
the third pole of the Hirschmann connector.
2. Install a 5 Amp fuse in line with the wire connected
to the first pole of the Hirschmann connector
(applies to both 12 and 24 VDC models).
3. Wire as follows. If using a Graco mating cable, the
wire color corresponding to the 4-Pole Hirschmann
connection point is provided in parenthesis.
Chassis Ground (-) to Hirschmann connection,
labeled number 2 (Black wire)
Battery (+) to Hirschmann connection, labeled
number 1 (White wire) - This source should
always provide a voltage supply.
Ignition (+) to Hirschmann connection, labeled
number 3 (Red wire) - This source should only
provide a voltage supply when the vehicle igni-
tion switch is on.