14 312054J
o-rings that may be attached (FIG. 15).
7. Add or remove output spacer washers (A) from the
meter valve assembly.
NOTE:
Add spacer washers (A) to increas output vol-
ume.
Remove spacer washers (A) to decrease output
volume.
8. Reassemble meter body on meter valve assembly.
Use a 5/8” wrench to tighten using only enough
force to seat output washers firmly (F
IG. 16).
9. Align hex flats so a deep well socket will slide down
to the meter body for assembly onto manifold.
10. Reassemble meter onto manifold using the 5/8”
deep well socket. Torque to 2-3 ft.-lbs.
11. Hand tighten the tube nut onto the meter and tighter
1/8 turn beyond hand tight.
NOTE: Tube nuts can be reused a maximum of 8
times after the initial tightening.
12. Reconnect tubing to manifold using a 7/16” wrench
to securely tighten fitting.
F
IG. 15
A
FIG. 16
NOTICE
Do not xceed 12 ft-lbs torque or meter damage may
occur.